The Village Hall is equipped with a stage complete with
stage lighting. Users who are familiar with the safe use and adjustment of
stage lighting are free to rearrange the lighting for their own events at their
own risk. However, please return the fixtures to their original positions and
focus once your event is completed, ready for the next hall users. Users who
fail to do this will be liable to a surcharge.
·
For overall stage and hall dimensions follow the
Facilities link here
·
The stage floor is 1 metre above hall floor level.
·
A stage extension is available, consisting of 4 x
1Msq sections that can be attached to the front of the stage.
·
The stage includes a proscenium arch 5.9m wide x
2.6m high. Tabs cover the arch, drawn to the centre from a pulley system Stage
Right.
·
2 x Strand Quartet PC 650W inc. filter frame and barndoors
·
2 x Strand Prelude F 650W inc. filter frame and barndoors
·
2 x Strand Prelude PC 650W inc. filter frame and barndoors
·
4 x P56 300W inc. filter frame
·
2 x P64 Longnose Parcan 1000W inc filter frame and barndoors
·
2 x P64 Shortnose 1000W
inc. filter frame
·
500W Floods x 2 for lighting FoH
·
Fairy Lights – 34 x 25W lamps in multiple colours in
a loop around the hall approximately 2.8m above the ground. The Fairy lights
connect to mains power Stage Left and can be switched on/off as required. There
is also a 16A to 15A adaptor cable available so that the fairy lights can be
connected into the dimmer rack.
·
2 x Flood Batten comprising of 8 x 150W lamps inc.
filter frames lighting the Cyc.
·
The configuration for each batten is 3 channels,
(Red R26, Green R90 and Blue R67) of which 2 channels each have 3 x 150W lamps
(Red and Blue), with the 3rd channel comprising of 2 x 150W lamps (Green). The
battens are daisy chained together so that the 3 colours can be controlled
independently from 3 channels if required.
·
1 x Zero88 Level Plus12 DMX Manual control desk
consisting of 2 x 12 channel presets.
·
2 x 6ch Zero88 Betapack II
dimmer DMX racks. Rated at 10A per channel. Each Betapack
II channel has 2 x 15A sockets
·
The Dimmers are wall-mounted Stage Left.
·
Datasheet: http://www.gradav.co.uk/images/pdfs/34.pdf
·
The Dimmers are connected to a 63A single phase
power supply
·
The hall 15A cabling system is centred back to a
patching panel adjacent to the dimmers allowing full cross patching. The
cabling system comprises of 22 x 15A sockets, 12 front of house and 10 on LX
bars above the stage.
·
2 x DMX sockets are available FoH
to connect the hall light control desk or any DMX compatible control desk.
(Both FoH, one at the rear of the hall, and the 2nd
approx 9.5m from Proscenium arch). Both sockets are wired back to a patching
panel beside the dimmers Stage Left. 1 x 5M and 1 x 20M DMX patching cables are
available to extend DMX from control desk to the FoH
sockets
·
2 x LX Boom’s mounted 2.6 Metres above the floor
level. Each boom extends 1.5 metres vertically upwards. Each Boom has 3 x 15A
sockets linked into the hall 15A light cabling
·
Each boom has 3 x Prelude/Quartet F/PC 650W
lanterns.
·
The Boom’s are mounted 3m from the proscenium arch,
each side of the stage.
·
2 x LX bars each with 3 x 15A sockets linked into
the hall 15A lighting. The LX bars are 4.2m above the FoH
floor.
·
Each LX bar has 1 x Par64 Longnose
1000W lantern, 1 x 500W flood for lighting FoH.
·
2 LX bars above the stage.
·
LX1 has 6 x 15A sockets linked into the hall stage
lighting cabling system. LX1 has mounted 4 x PAR56 and 2 x PAR64 (shortnose) lanterns.
·
LX2 is mounted in front of the cyc
and has 2 x Flood battens mounted
·
A bar is in situ from which a cyc
can be hung. The bar is flown in/out via hemp to allow easy hanging from stage
floor level. Unfortunately there is not enough room above the stage in which to
fly the cyc out.
·
Woodbury Hall has no full-time lighting technician.
However Alan Pewsey is available to advise on the
lighting installation and will do his best to assist where possible if you need
help with a lighting design for your event. Alan is a volunteer so please give
plenty of notice if assistance is required. Alan can be contacted via email on alan@pewseys.co.uk.
Appendix A – Hall Plan.